Audi TT Coupe 2015 > Calibration Tool VAS6350 , Installing and Aligning

Calibration Tool VAS6350 , Installing and Aligning


Audi TT Coupe 2015 >,Audi TT Coupe 2015 >
Special tools and workshop equipment required Calibration Unit VAS6350A Vehicle Diagnostic Tester

The Calibration Tool VAS6350 consists of the following parts:

Calibration Tool - Wheel Center Mountings VAS6350/1 Calibration Tool - Spacing Laser VAS6350/2 Calibration Tool - Linear Laser VAS6350/3

After performing service work on the vehicle, it may be necessary to re-calibrate the rearview camera system. In detail, this is the case after:

Rearview Camera R189 Removal and Installation Collision repairs on rear lid Changes to the axle alignment on the rear axle

Calibration Requirements

The camera lens must be clean. The vehicle must be standing on a firm and level surface. There must be sufficient open space around the vehicle. The parking brake must be set. The steering wheel must be in the 0 liition and the wheels must be straight. All doors and the rear lid must be closed. No one should be in the vehicle. The vehicle must not be loaded (curb weight). Before each calibration: turn on the ignition.

Installed Calibration Tool VAS6350 Overview


Electrical System|Communication|Communication|Rearview Camera System|Rearview Camera System, Calibrating
  1. Audi Rings in the Rear Lid
  2. Calibration Tool - Wheel Center Mountings VAS6350/1
  3. Right Angle Bracket Calibration Tool - Spacing Laser VAS6350/2 mount
  4. Level On the calibration board For checking the horizontal liition
  5. Calibration Tool - Spacing Laser VAS6350/2 Refer to the Owner's Manual for notes on the operation.
  6. Plastic Foot Three on underside of the calibration board Adjustable for aligning horizontal liition of the calibration board
  7. Calibration Tool - Linear Laser VAS6350/3 On the calibration board Switching on and off. Refer to the Owner's Manual.
  8. Calibration Board Between the mounts on the calibration board and the Calibration Tool - Wheel Center Mountings VAS6350/1 dimension a 1.47 m through 1.90 m.
  9. Left Angle Bracket Calibration Tool - Spacing Laser VAS6350/2 mount
  10. Calibration Tool - Wheel Center Mountings VAS6350/1

Calibration Board Orientation

liition the calibration platform behind the vehicle at a distance of 1.47 m to 1.90 m to the rear wheels, see dimension A in the illustration. Refer to Go to article. Bring the Calibration Tool VAS6350 into a horizontal liition. Twist the plastic feet under the calibration board so that the air bubble in the level is located exactly in the center of the indicator arrow .
Electrical System|Communication|Communication|Rearview Camera System|Rearview Camera System, Calibrating
WARNING

Make sure light does not reflect off the calibration board.

Reflections affect the Rearview Camera R189 and may make it imlisible to perform the calibration.

Switch on the Linear Laser VAS6350/3A 1 on the calibration board and adjust the entire Calibration Tool VAS6350 so that the laser beam hits the center of vehicle rear above the Audi rings.
Electrical System|Communication|Communication|Rearview Camera System|Rearview Camera System, Calibrating
Check that the Audi rings are centered on the rear. Correct the laser beam accordingly.

Continue calibrating the Rearview Camera R189 . Refer to Go to article “ Rearview Camera R189 , Calibrating ”
Audi TT Coupe 2015 >,Audi TT Coupe 2015 >
.